XCON: MTA Terminates Unexpectedly with Event ID 9405 (159193)
The information in this article applies to:
- Microsoft Exchange Server 4.0
This article was previously published under Q159193 SYMPTOMS
The Microsoft Exchange Message Transfer Agent (MTA) terminates
unexpectedly with an event similar to the following (as viewed in the
Application Event Log):
Event Id: 9405
Source: MSExchangeMTA
Type: Error
Category: Field Engineering
Description:
An unexpected error has occurred which may cause the MTA
to terminate. Error: Exception c0000005 occurred at Address
0x02163E04. (16)
This failure may be coincident with the addition of a new Directory
Replication Connector, or at MTA startup.
CAUSE
The MTA code that generates the text file GWART0.MTA did not use a data
structure large enough to accommodate the routing information obtained
through directory replication.
WORKAROUND
There is no workaround for this problem.
STATUS
Microsoft has confirmed this to be a problem in Exchange version 4.0.
This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix KB159193 |
---|
|