XADM: MTA Terminates Unexpectedly with Events 251 and 9405 (159174)
The information in this article applies to:
- Microsoft Exchange Server 4.0
This article was previously published under Q159174 SYMPTOMS
The Microsoft Exchange Message Transfer Agent (MTA) version 4.0 may
terminate unexpectedly with the following events:
Event Id: 9405
Source: MSExchangeMTA
Type: Error
Category: Field Engineering
Description:
An unexpected error has occurred which may cause the MTA
to terminate. Error: Exception e0020004 occurred at Address
77f3cbcd. [BASE DISP:ROUTER 11] (16)
Event Id: 9405
Source: MSExchangeMTA
Type: Error
Category: Field Engineering
Description:
An unexpected error has occurred which may cause the MTA
to terminate. Error: Double acquire of semaphore 2810
[BASE DISP:ROUTER 11] (16)
Event Id: 251
Source: MSExchangeMTA
Type: Warning
Category: Configuration
Description:
A fatal internal MTA error occurred. Entity control
block reassigned because of a configuration error.
Statistics for entity /O=BANDS/OU=EMERALD/CN=CONFIGURATION
/CN=CONNECTIONS/CN=SITE CONNECTOR (MARIAH) have been lost.
[MTA DISP:ROUTER 11 445] (16)
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 4.0.
This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix KB159174 |
---|
|