XADM: MTA Error 9405 (157708)
The information in this article applies to:
- Microsoft Exchange Server 4.0
This article was previously published under Q157708 SYMPTOMS
You may see the following error reported by the Microsoft Exchange Server
Message Transfer Agent (MTA):
Event #9405 An unexpected error has occurred which may cause the MTA to
terminate.
Error: Exception c0000005 occurred at address 2031561 [BASE
KERNEL, 27] (16)
CAUSE
One of the causes of this error is a timing error occuring during a
connection attempt. The MTA sends a connection request at the transport
layer,
and may receive a connection confirm for the transport layer before the MTA
has prepared the connection at the session layer (CN SPDU).
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server,
version 4.0.
This problem was corrected in the latest Microsoft Exchange 4.0 Server U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base:
MORE INFORMATION
This timing issue was resolved by readying the session layer connection
request (CN SPDU) before sending the connection request for the transport
layer.
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix KB157708 |
---|
|