This article was previously published under Q157699 SYMPTOMS
The Microsoft Exchange Message Transfer Agent (MTA) will fail to process
Read and Delivery Receipts when messages are sent from Microsoft Exchange
to a Wang Office Gateway via the Microsoft Exchange X.400 Connector.
CAUSE
The MTA does not handle the Per Message Flag as specified in the 1984 X.400
specification.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 4.0. This problem was corrected in the latest Microsoft Exchange
Service Pack. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|