Windows NT May Hang Using SNA Server 2.11 SP1 w/Digi Sync SDLC (157327)
The information in this article applies to:
- Microsoft SNA Server 2.11 SP1
This article was previously published under Q157327 SYMPTOMS
When you use the new Digi Sync SDLC driver included with SNA Server 2.11
Service Pack 1, the Microsoft Windows NT computer may hang (for example,
mouse and keyboard input has no effect) after the SDLC connection stays
pending, if a misconfigured modem or bad cable (either V.35 or RS-232, as
appropriate) are being used.
NOTE: The Digi Sync SDLC adapter supports either a V.35 or RS-232
interface. This problem has been observed with either interface.
CAUSE
The problem is being investigated by Digi Corporation.
RESOLUTION
To resolve the problem, the SDLC cable and modem should be checked
for possible misconfiguration. All reported cases of hang problems were
due to either a improper synchronous modem cable or misconfigured
modem (for example, a modem not configured for SDLC or synchronous
operation).
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server 2.11
Service Pack 1. We are researching this problem and will post new
information here in the Microsoft Knowledge Base as it becomes available.
Modification Type: | Major | Last Reviewed: | 6/13/2001 |
---|
Keywords: | kb3rdparty kbbug kbinterop KB157327 |
---|
|