XADM: MTA Restart Fails and Logs Error 2051 (157058)



The information in this article applies to:

  • Microsoft Exchange Server 4.0

This article was previously published under Q157058

SYMPTOMS

After a failure and a subsequent failed restart attempt, the Microsoft Exchange Server Message Transfer Agent (MTA) logs an event similar to the following:
Event ID: 2051
Source: MSExchangeMTA
Description: A fatal internal MTA error occurred. Contact Microsoft Product Support Services. An illegal GET from element 3CB84D01 occurred at offset 2073. [BASE DISP:FANOUT 14 8] (16)

CAUSE

If a failure occurred during the processing of a message, upon restart, key routing information for some addresses on the recipients list may not be consistent, causing the fatal error described above.

STATUS

Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Modification Type:MinorLast Reviewed:4/28/2005
Keywords:kbbug kbfix kbusage KB157058