Invalid Page Fault in Shell32.DLL With Lightspeed NVS32 (155517)
The information in this article applies to:
- Microsoft Word for Windows 95
- Microsoft Word for Windows 95 7.0a
This article was previously published under Q155517 SUMMARY
When you attempt to open or save a Word document located on a network
drive, you get the following error message:
Winword caused an invalid page fault in module Shell32.dll
CAUSE
This problem occurs when you have installed the Wang SNA emulation package,
LightSpeed NVS32 for Windows 95, version 1.0.5 or earlier.
STATUS
LightSpeed development has confirmed that this is a problem in LightSpeed
NVS32 for Windows 95, version 1.0.5 and earlier. This problem has been
fixed in LightSpeed NVS32 for Windows 95, version 1.0.6.
RESOLUTION
To eliminate this problem, install LightSpeed NVS32 for Windows 95, version
1.0.6. To obtain this product, contact LightSpeed Technical Support at
(805) 326-8324.
The LightSpeed products discussed here are manufactured by LightSpeed, a
vendor independent of Microsoft; we make no warranty, implied or otherwise,
regarding these products' performance or reliability.
Modification Type: | Minor | Last Reviewed: | 8/17/2005 |
---|
Keywords: | kbinterop KB155517 |
---|
|