XCON: Dynamic RAS Error Msg: An Interface Error Has Occured (153758)
The information in this article applies to:
- Microsoft Exchange Server 4.0
- Microsoft Exchange Server 5.0
- Microsoft Exchange Server 5.5
This article was previously published under Q153758 SYMPTOMS
When you use the Dynamic RAS Connector between two Microsoft Exchange
Servers where Server A dials Server B to transfer mail and Server A
disconnects after 20-30 seconds, the Windows NT Event Log might show the
following event:
An interface error has occurred. An MtaBindBack over RPC has failed.
Locality Table (LTAB) index: 5, NT/MTA error code: 1723. [BASE IL
INCOMING RPC 190 507] (14).
The same connection might be successful if Server B dials Server A.
CAUSE
Either the Override Account Information on the RAS Connector override tab
is incorrect or Windows NT Service Pack 4 has not been properly installed.
The latter might occur if protocols and components were added to the
Windows NT 3.51 server after Service Pack 4 was installed.
RESOLUTION
Either correct the Override Account Information or reinstall Windows NT
3.51 Service Pack 4.
NOTE: Service Pack 4 should be installed on the Microsoft Exchange Server
that is not accepting the connection.
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbprb kbusage KB153758 |
---|
|