SMS Administrator Unable to Display Properties of Two NICs (153396)
The information in this article applies to:
- Microsoft Systems Management Server 1.0
- Microsoft Systems Management Server 1.1
- Microsoft Systems Management Server 1.2
This article was previously published under Q153396 SYMPTOMS
When two identical network interface cards (NICs) are installed on a
Windows NT client, the SMS Administrator is sometimes unable to display
both cards when using the "View a table of data records" display in the
"Netcard Properties" window.
CAUSE
This problem occurs when the parameters retrieved by Invwin32.exe are
equal for both cards (example with an ENET-TR Netflex/Netflex-2):
Manufacturer = <ENET-TR Netflex/Netflex-2 COMPAQ>
IRQ = 0
Port Address = <nothing>
The "IRQ=0" means there is no IRQ parameter in the registry (in the
HKEY_LOCAL_MACHINE subtree, at the subkey
SYSTEM\CurrentControlSet\Services\NETFLX1\Parameters).
WORKAROUNDSTATUS
Microsoft has confirmed this to be a problem in Systems Management Server
versions 1.1 and 1.2. We are researching this problem and will post new
information here in the Microsoft Knowledge Base as it becomes available.
| Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
|---|
| Keywords: | kbInventory kbnetwork KB153396 |
|---|
|