Initialization Failure in Rasman.dll When Shutting Down (152428)
The information in this article applies to:
- Microsoft Windows NT Server 3.51
This article was previously published under Q152428 SYMPTOMS
Windows NT may stop responding on shutdown and/or the following message may
appear:
Initialization of the dynamic link library
c:\winnt35\system32\rasman.dll failed. The process is terminating
abnormally.
CAUSE
The service controller issues an asynchronous TransactNamedPipe and asks it
to read four bytes to a stack variable. It then waits two minutes for the
TransactNamedPipe to finish. After two minutes it returns from the function
without canceling the operation. When the operation finishes it overwrites
the stack.
RESOLUTION
The I/O operation is canceled before the function returns.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51.
This problem was corrected in the latest Windows NT 3.51 U.S. Service
Pack. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 8/8/2001 |
---|
Keywords: | KB152428 |
---|
|