Stop 0x0A When NWNBLNK Accesses Memory in Free Pool (152194)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Server 3.51
This article was previously published under Q152194 SYMPTOMS
Computers that use NWLink NetBIOS may experience blue stop screens with a
bugcheck code of 0x0A: IRQL_NOT_LESS_OR_EQUAL.
Examination of a crashdump, or a live debug, usually reveals that the
exception occurred in function KeAcquireSpinLock called from function
HandleConnectionZero, and is caused by NWLNKNB accessing memory that is
either in free pool or which has been acquired by another process. CAUSE
Due to incorrect synchronization logic, there is an exposure in NWNBLNK
that causes a bugcheck when multiple requests are processed for the same
NWNBLNK connection. If one of the requests is a disconnect, in some rare
circumstances the disconnect is completed first, freeing the memory
structure used for the NWNBLNK connection structure. When processing of the
remaining requests resume, a Stop 0x0A results when attempting to access
the now freed (and possibly reused) connection structure.
Due to the nature of this problem it occurs very infrequently. When the
problem does occur, it is most likely to be seen on faster computers,
particularly on multi-processor computers, such as multi-processor
DEC Alpha servers.
RESOLUTION
Apply the hotfix described below or upgrade to Windows NT 4.0.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51. A
supported fix is now available, but is not fully regression-tested and
should be applied only to systems experiencing this specific problem.
Unless you are severely impacted by this specific problem, Microsoft
recommends that you wait for the next Service Pack that contains this fix.
Contact Microsoft Product Support Services for more information.
Modification Type: | Major | Last Reviewed: | 10/23/2003 |
---|
Keywords: | kbnetwork KB152194 |
---|
|