System Error 71 and License Manager (149522)
The information in this article applies to:
- Microsoft Windows NT Server 3.51
This article was previously published under Q149522 SYMPTOMS
Clients may receive the following error when they try to connect to a
Windows NT 3.51 server:
System Error 71
No more connections can be made to this remote computer at this time
because there are already as many connections as the computer can
accept.
CAUSE
One possible cause for this error is that License Manager has not been set
up to grant enough connections to meet the client's demands. In this case,
go into the Control Panel's Licensing tool and set up License Manager with
the appropriate number of client licenses per seat or per server.
Another possible cause of this error message is that License Manager has a
corrupted or incorrect purchase history record. The Cpl.cfg file in the
%SystemRoot%\System32 directory is responsible for maintaining this
information.
Modification Type: | Major | Last Reviewed: | 2/20/2002 |
---|
Keywords: | KB149522 |
---|
|