Remote Control Fails with Lowercase Computer Name (149495)
The information in this article applies to:
- Microsoft Systems Management Server 1.0
- Microsoft Systems Management Server 1.1
This article was previously published under Q149495 SYMPTOMS
If a Windows client was originally inventoried by SMS with a lowercase
NetBIOS computer name, Remote Control may fail with the following error:
UNABLE TO LOCATE CLIENT
MORE INFORMATION
Windows versions 3.11 and later automatically convert the computer name to
uppercase when writing to the System.ini file.
If the computer name in the System.ini or Sms.ini file is changed to
lowercase after the initial inventory, the problem does not occur.
This problem only occurs if the computer was originally inventoried with a
lowercase name and appears with a lowercase name in the SMS Administrator.
WORKAROUND
To work around this problem:
- Edit the ComputerName= in the [Network] section of System.ini so that
the computer name is entirely in uppercase characters.
- Connect to the SMS_SHR on your logon server.
- At a command prompt, make that share your current drive and change your current directory to X86.BIN.
- Run invdos /f.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server
versions 1.0 and 1.1. This problem has been corrected in Systems Management
Server version 1.2.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|
Keywords: | kbnetwork kbRemoteProg kbtshoot KB149495 |
---|
|