VTCPRACT Err Msg: The Network Telesystems PPP/SLIP... (146438)
The information in this article applies to:
- Microsoft Windows 95
- Microsoft Windows 98
This article was previously published under Q146438 SYMPTOMS
When you start Windows 95 or Windows 98, you may receive one of the following error
messages:
- VTCPRACT
The network telesystems PPP/SLIP virtual device driver is not
installed, so the networking telesystems TCP driver will not be loaded.
- VTCPRACT
Neither the Network Telesystems nor the Shiva PPP/SLIP virtual device
driver is installed.
CAUSE
These error messages can occur if an incomplete set of third-party
networking drivers is installed.
RESOLUTION
To work around these error messages, disable the following three lines in
the [386Enh] section of the System.ini file in the Windows folder:
Device=<path>Vntstimd.exe
Device=<path>Vntspsd.386
Device=<path>Vtcprac.386
To disable a line in the System.ini file, place a semicolon (;) at the
beginning of the line. NOTE: This also applies for the files "vntstimd.exe" and "dial.386" which are contained in the same section [386Enh].
MORE INFORMATION
VTCPRACT is part of the Delphi Online service.
The product discussed here is manufactured by a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this
product's performance or reliability.
Modification Type: | Minor | Last Reviewed: | 12/16/2004 |
---|
Keywords: | kb3rdPartyNetClient KB146438 |
---|
|