Using IBMTOK.DOS on Fast Computers Results In Error 36 (146106)
The information in this article applies to:
- Microsoft LAN Manager 2.2c
- Microsoft Network Client for MS-DOS 3.0
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q146106 SYMPTOMS
When you load a real-mode protocol, such as MS-DLC, TCP/IP or NetBEUI, on a
LAN Manager 2.2c, a Network Client 3.0 for MS-DOS or a Windows for
Workgroups 3.11 computer using IBMTOK.DOS for a token ring adapter, the
following error message appears:
Error 36: Unable to bind. Hardware failure.
CAUSE
This problem occurs on any computer running at a CPU speed greater than 60
Mhz. The IBMTOK.DOS driver does not work properly at CPU speeds greater
than 60 Mhz.
RESOLUTION
To correct this problem, download IBMTOKR.EXE, a self-extracting file that
includes the new IBMTOK.DOS driver (dated 10/18/94), from the
following service:
- Internet (anonymous FTP)
ftp ftp.microsoft.com
Change to the Softlib/Mslfiles folder.
Get IBMTOKR.EXE
For additional information about , please see the following
article(s) in the Microsoft Knowledge Base: 119591 How to Download Microsoft Support Files from Online
Services
Modification Type: | Major | Last Reviewed: | 11/13/2003 |
---|
Keywords: | KB146106 |
---|
|