SYMPTOMS
When you select the Reinstall option to reinstall Microsoft Access for
Windows 95 version 7.0 to a workstation (run from server Setup), and then
start Microsoft Access, you may receive the following error message:
Microsoft Access can't start the data access object (DAO) and so it
can't continue.
Solution
Run Setup to reinstall Microsoft Access.
When you click OK, the following message appears:
A system error occurred, or there isn't enough free memory to start
Microsoft Access. Close unneeded programs and try again.
When you click OK, Microsoft Access does not start.
CAUSE
The Reinstall option removes some key registry settings that are necessary
for Microsoft Access 7.0 to run correctly.
RESOLUTION
Select the Remove All option instead of the Reinstall option. Then run
Setup from the server.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Access 7.0. This
problem no longer occurs in Microsoft Access 97.
REFERENCES
See the "Microsoft Access Network Installation" topic in the Network.txt
file included with Microsoft Access 7.0.
For more information about the Microsoft Access 2.0 version of this
article, please see the following article in the Microsoft Knowledge
Base:
120058 ACC2: Errors After Reinstalling MS Access to Workstation
Modification Type: | Major | Last Reviewed: | 6/25/2002 |
---|