Event 582 may occur when running Win 3.x APPC or CPIC App (139786)
The information in this article applies to:
- Microsoft SNA Server 2.1
- Microsoft SNA Server 2.11
This article was previously published under Q139786 SYMPTOMS
When you run a 16-bit Windows APPC or CPIC application, the SNA Server
Windows 3.x client software displays the following error message:
Error 582:
No name supplied in the parameter list for this component
CAUSE
There are two causes for this problem:
- If the SNA Server 2.1 Windows 3.x client software is being used, and
if the SNA client software is unable to determine the Windows
application name, or parse for its filename (used for internal
reasons only), the SNA client will display this error. This problem
is fixed in the SNA Server 2.11 Windows 3.x client software.
- When using the SNA Server 2.11 Windows client software, if the
filename of the CPIC or APPC application happens to include a "0"
(zero), the SNA client incorrectly parses the filename (again, used
for internal reasons only), causing the error to occur.
RESOLUTION
If the SNA Server 2.11 Windows 3.x client software is being used and
the application filename includes a "0", a simple workaround would be
to rename the file so it doesn't include the "0" character
An update to the SNA Server 2.11 Windows 3.x client software corrects
this problem.
The updated Windows 3.x client file is:
<winroot>\SYSTEM\WDMOD.DLL
STATUS
Microsoft has confirmed this to be a problem in SNA Server for Windows NT.
This problem was corrected in the latest SNA Server for Windows NT, 2.11
U.S. Service Pack. For information on obtaining the Service Pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 10/23/2003 |
---|
Keywords: | KB139786 |
---|
|