STOP Msg: 0x0000007B Installing Windows NT on HP Vectra XU/XUC (137860)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Server 3.5
- Microsoft Windows NT Server 3.51
This article was previously published under Q137860 SYMPTOMS
When you install Windows NT 3.5 or 3.51 on a Hewlett-Packard (HP) Vectra
XU/XUC P5 Pentium-based computer using an on-board AMD SCSI controller, the
following STOP Message appears after Setup completes the mass storage
device detection and reboots your computer:
STOP: 0x0000007B
INACCESSIBLE_BOOT_DEVICE
RESOLUTION
To correct this problem:
- Ensure the BIOS version of your Vectra computer is 5.08 or above. If
it is not, contact HP Vectra DeskTop Support at (970) 635-1000 for a
BIOS update.
- Obtain VJS2NIUS.EXE, which contains a new AMD SCSI controller driver
AMSINT.SYS, from the HP Bulletin Board Service at (208) 344-1691 or HP's
web site at http://www.hp.com. Extract VJS2NIUS.EXE on another computer.
- Run Windows NT Setup by typing the following (which creates the Windows
NT Setup floppy disks):
WINNT /OX
-or-
WINNT32 /OX - Replace the AMSINT.SYS driver on the third Windows NT Setup floppy
disk with the SCSI driver obtained from HP (Step 2 above).
- Continue Windows NT Setup.
Modification Type: | Major | Last Reviewed: | 12/16/2003 |
---|
Keywords: | KB137860 |
---|
|