SYMPTOMS

After you add another Compaq SmartSCSI Array controller and configure it for hardware RAID level 5 array using the EISA Configuration utility, Windows NT reports the hard drive sizes incorrectly.

CAUSE

This problem occurs if the SmartSCSI Array controller's ROM information is not reset after configuring the controller using the EISA Configuration utility.

RESOLUTION

To correct this problem:
  1. Reboot your computer with the EISA Configuration Utility disk in Drive A.
  2. Press CTRL+A to enable and view Advanced mode configuration.
  3. Select System Configuration and then select Configure Hardware.
  4. Select Review or Modify Hardware Settings.
  5. Select View or Edit Details.
  6. From the list of controllers, select SmartSCSI Array Controller.
  7. Choose Reset Controller.
  8. Save and exit the utility.
  9. Reboot the computer and restart Windows NT.
For more information, contact Compaq Technical Support at (800) 652-6672.