Accton MPX EN1652 Network Adapter Not Detected (136407)
The information in this article applies to:
This article was previously published under Q136407 SYMPTOMS
The Accton MPX EN1652 NE2000-compatible network adapter in your computer
may not be detected by Setup or the Add New Hardware Wizard.
CAUSE
This problem can occur if the network adapter is configured to use one of
the following base I/O addresses:
Although these are valid settings for the network adapter, Windows 95 does
not query these addresses when it searches for NE2000-compatible network
adapters.
RESOLUTION
To work around this problem, use either of the following methods:
- Manually install the Accton MPX EN1652 network adapter as an NE2000-
compatible network adapter by following these steps:
- Click the Start button, point to Settings, and then click Control
Panel.
- Double-click the Add New Hardware icon, and then click Next.
- Click the No option button, and then click Next.
- Double-click Network Adapters.
- In the Manufacturers box, click Novell/Anthem. In the Models box,
click NE2000 Compatible.
- Click OK, and then click Next.
- Use the configuration utility included with the network adapter to
configure it to use one of the following valid base I/O addresses:
After you configure the network adapter to use one of these base I/O
addressed, run the Add New Hardware Wizard to install the network
adapter.
Modification Type: | Major | Last Reviewed: | 12/17/2000 |
---|
Keywords: | KB136407 |
---|
|