OLEDLG.DLL and MSVCRT20.DLL Not Found For Crystal Reports (136037)
The information in this article applies to:
- Microsoft Systems Management Server 1.1
This article was previously published under Q136037 SYMPTOMS
When you attempt to run Crystal Reports version 3.0.1.29 included with
Systems Management Server 1.1 in Windows NT 3.5, the following error
message appears:
The dynamic link library OLEDLG.dll could not be found in the
specified path x:\CRW;<system paths>
where x is the drive where Systems Management Server 1.1 is installed.
The following error message appears when you choose OK:
The dynamic link library MSVCRT20.DLL could not be found in the
specified path x:\CRW;<system paths>
where x is the drive where Systems Management Server 1.1 is installed.
CAUSE
Your OLEDLG.DLL and MSVCRT20.DLL files are not in the Crystal Reports
directory or the system paths.
RESOLUTION
To correct this problem:
- Upgrade to Windows NT 3.51.
-or-
- Reinstall the OLEDLG.DLL and MSVCRT20.DLL files into the correct
directories:
- Copy OLEDLG.DL_ from the \I386 directory on the Windows NT 3.51
compact disc to the \CRW directory or the %SystemRoot%\SYSTEM32
directory.
- Run EXPAND.EXE to expand the compressed OLEDLG.DL_ file to the name
OLEDLG.DLL.
- Copy the MSVCRT20.DLL file from the \DRVLIB\COMM\ECCI\X86 directory
on the Windows NT 3.51 compact disc to the \CRW directory or the
%SystemRoot%\SYSTEM32 directory.
For additional information, contact Crystal Technical Support at
(604) 669-8379.
The third-party product discussed here is manufactured by a vendor
independent of Microsoft; we make no warranty, implied or otherwise,
regarding this product's performance or reliability.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|
Keywords: | kb3rdparty kbother KB136037 |
---|
|