IOCTL_NDIS_QUERY_ALL_STATS Causes STOP Msg in Windows NT 3.51 (135553)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Server 3.51
This article was previously published under Q135553 SYMPTOMS
If your application querys a Miniport MAC driver from user mode using
DeviceIoControl with the IoCtl Opcode of IOCTL_NDIS_QUERY_ALL_STATS, this
STOP message appears:
STOP: 0x0000001E (0xC0000005 0x801704a7 0x00000001 0x00000001)
This error occurs sporadically.
CAUSE
The NDIS.SYS driver is referencing an invalid pointer.
RESOLUTION
To correct this problem, install the latest U.S. Service Pack for Windows
NT version 3.51.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51.
This problem has been corrected in the latest U.S. Service Pack for Windows
NT version 3.51. For information on obtaining the Service Pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 10/30/2003 |
---|
Keywords: | kbnetwork KB135553 |
---|
|