Cannot Boot Windows NT 3.5x From Duplexed Mirror Drive (134387)
The information in this article applies to:
- Microsoft Windows NT Server 3.5
- Microsoft Windows NT Server 3.51
This article was previously published under Q134387 SYMPTOMS
If you have a duplex mirror and the primary drive fails, you may not
be able to boot from your Fault tolerant boot floppy.
CAUSE
This problem occurs when the adapter for the shadowed drive has the BIOS
disabled. Windows NT 3.5 and later use Multi instead of Scsi in the
BOOT.INI file. If the BIOS is disabled, Multi does not find the controller.
RESOLUTION
To work around this problem:
- Enable the BIOS on the second adapter and change Scsi references to
Multi in your BOOT.INI file.
- Change the Multi references to Scsi in the BOOT.INI file on the floppy
disk you are booting from. Copy your SCSI driver to the floppy disk.
Rename it NTBOOTDD.SYS. Change the arc path read to read:
- Move the previously shadowed drive to the first controller.
Modification Type: | Major | Last Reviewed: | 11/4/2003 |
---|
Keywords: | KB134387 |
---|
|