SNA Server Win 3.x APPC/CPIC Apps Hang Using Blocking Hook (133312)
The information in this article applies to:
- Microsoft SNA Server 2.0
- Microsoft SNA Server 2.1
- Microsoft SNA Server 2.11
- Microsoft SNA Server 3.0
- Microsoft SNA Server 4.0
This article was previously published under Q133312 SUMMARY
When using the SNA Server Windows 3.x client WinAPPCSetBlockingHook() or
WinCPICSetBlockingHook() calls from a Windows 3.x application, the blocking
hook function must call PeekMessage, or the Windows 3.x application will
hang.
The SNA Server Windows 3.x CPIC and APPC API interfaces rely on the use of
Windows messages to process an API call on behalf of the calling
application. If the application registers it's own blocking hook function
that blocks the reception of Windows messages, the calling application will
hang.
Modification Type: | Minor | Last Reviewed: | 2/11/2004 |
---|
Keywords: | kbnetwork kbprogramming KB133312 |
---|
|