STOP Msg: 0x0000003F NO_MORE_SYSTEMS_PTES Repetitive I/O on MIPS (130783)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Server 3.5
- Microsoft Windows NT Server 3.51
This article was previously published under Q130783 SYMPTOMS
When you perform repetitive reads and writes to your floppy disk on a MIPS
computer, the STOP Message appears:
STOP: 0x0000003F 0x00000000,0x00000000,0x00000000,0x00000000)
NO_MORE_SYSTEMS_PTES
CAUSE
During repetitive floppy disk I/O, the Memory Descriptor List (MDL) becomes
corrupted and supplies erroneous information leading Windows NT to believe
that no more Page Table Entries (PTES) exist.
NOTE: You can observe the decrease in PTES on the system during the floppy
disk I/O by monitoring the counter "Free System Page Table Entries" for the
Memory object in Performance Monitor.
RESOLUTION
To correct this problem, upgrade to Windows NT 3.51 (if you have not
already done so) and install the latest U.S. Service Pack for Windows NT
version 3.51.
STATUS
Microsoft has confirmed this to be a problem in Windows NT versions 3.5 and
3.51. This problem has been corrected in the latest U.S. Service Pack for
Windows NT version 3.51. For information on obtaining the Service Pack,
query on the following word in the Microsoft Knowledge Base (without the
spaces):
Modification Type: | Major | Last Reviewed: | 12/15/2003 |
---|