Error 33 on Alternate RPC Calls (129148)
The information in this article applies to:
- Microsoft LAN Manager 2.2
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q129148 SYMPTOMS
Every other RPC call fails when RPC applications are running on Windows and
Windows for Workgroup clients. If the failed RPC call is issued a second
time, it completes successfully.
CAUSE
Some DCE compliant RPC servers shutdown the RPC connection after a period
of inactivity. The 16-bit Windows RPC client does not respond to the
shutdown request. This prevents the client from cleanly closing the
connection to the RPC server. After an extended period of time, the RPC
server closes the connection even if the 16-bit RPC client does not
respond.
STATUS
Microsoft has confirmed this to be a problem in the RPC16C3.DLL file that
ships with Windows NT version 3.5 SDK. A fix to this problem is in
development, but has not been regression-tested and may be destabilizing in
production environments. Microsoft does not recommend implementing this fix
at this time. Contact Microsoft Product Support Services for more
information on the availability of this fix.
Modification Type: | Major | Last Reviewed: | 10/23/2003 |
---|
Keywords: | KB129148 |
---|
|