Compaq ProsigniaVS May Fail to Obtain SFM Routing Information (129121)
The information in this article applies to:
- Microsoft Windows NT Server 3.5
This article was previously published under Q129121 SYMPTOMS
When you run Services for Macintosh (SFM) on a Compaq ProsigniaVS running
Windows NT Server 3.5 on the same network with a Novell NetWare 3.12
network server running AppleTalk, the Compaq machine may fail to respond to
AppleTalk Lookup Requests.
Hardware
--------
Compaq ProsigniaVS
Compaq Fast SCSI-2 Controller w/1GB SCSI Drive
Compaq Integrated NetFlex - L ENET Controller
Servers
-------
NetWare 3.12 running Macintosh services.
Compaq running NTS 3.5 and SFM. (Build 807, SSD 1.14)
Workstation
-----------
Power Macintosh 7100/66AV (System 7.5)
If the NetWare server starts before the Compaq running Windows NT 3.5 and
defines a zone, the Compaq Server is not seen on the available servers list
in Chooser on the Mac. If you define the zone on the Windows NT 3.5
computer and start it first, you can see both the Windows NT machine and
the Novell server. If you define a separate zone on the Windows NT
computer, the zone shows up, but there are no available servers listed in
Chooser. If you go into Control Panel, choose Network on the Mac, and try
to switch zones, it reports that only the Novell zone exists. This problem
does not occur with Non-Compaq computers or Compaq computers running Non-
Compaq NICs.
WORKAROUND
To work around this problem:
- Define the zones on the Windows NT 3.5 computer and start if first
-or-
- Use a different type of network interface card (NIC) in the Windows NT
3.5 machine.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5. We
are researching this problem and will post new information here in the
Microsoft Knowledge Base as it becomes available.
Modification Type: | Major | Last Reviewed: | 10/3/2003 |
---|
Keywords: | KB129121 |
---|
|