SYMPTOMS

When Package Command Manager (PCM) for Windows 3.x tries to run a Visual Basic Setup Wizard setup program, the setup program prompts for floppy disks, even though all the necessary files are located in the package directory along with the Setup.exe file.

Running the same command from File Manager works correctly.

This problem also occurs with OMNIWIN.

CAUSE

The Visual Basic Setup Wizard, Setup.exe, spawns Setup1.exe and then exits. When PCM (PCMWIN16) detects the close of Setup.exe, it expects setup is complete, and deletes the network connection to the package share. Thus, when Setup1.exe looks for necessary files, it cannot find them, and prompts for disks.

NOTE: Setup1.exe is only the default name of the file spawned by Setup.exe. Developers are free to name it differently. See Setup.lst for the filename that is actually being used.

STATUS

Microsoft has confirmed this to be a problem in Systems Management Server versions 1.0 and 1.1. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

The products included here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Modification Type:MinorLast Reviewed:6/14/2005