STOP 0x0A in STREAMS.SYS with DEC Pathworks Loaded (127775)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Server 3.5
This article was previously published under Q127775 SYMPTOMS
When you use the Windows NT version 3.5 DEC Pathworks drivers, the
following STOP message may appear:
STOP: 0x0000000A
CAUSE
STREAMS.SYS does not behave correctly when the transport takes longer to
complete a connect request than the redirector allows. In this case, the
redirector first cancels the connect IRP, then later issues a disconnect.
STREAMS.SYS erroneously accepts the disconnect and crashes.
The disconnect should be rejected since the cancel issued a disconnect to
the transport.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5.
This problem has been corrected in the latest U.S. Service Pack for Windows
NT version 3.5. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Modification Type: | Major | Last Reviewed: | 11/3/2003 |
---|
Keywords: | KB127775 |
---|
|