SMS Administrator Err Msg: Socket () failed, 10047 (126158)
The information in this article applies to:
- Microsoft Systems Management Server 1.0
This article was previously published under Q126158 SYMPTOMS
When you attempt to use Systems Management Server Administrator to
remotely control a NetWare client, the following error message appears and
remote control is not available for any NetWare clients:
Socket () failed, 10047
CAUSE
Although remote control of NetWare clients uses IPX sockets, SMS
Administrator requires the NetBIOS NWBLINK driver.
MORE INFORMATION
NetBIOS support for NWLINK (NWBLINK) is installed under Windows NT when you
install NWLINK. However, if you install a Windows NT service that requires
NWLINK, and you have not yet installed NWLINK support, NWBLINK is not
installed. This happens when you install Gateway Services for Netware
(GSNW) on a Windows NT server.
RESOLUTION
To correct this problem, remove and reinstall NWLINK so that NWBLINK is
installed, and then install the other software that depends on NWLINK.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|