UNCONF: PRB: Error in SCX: Objtype=1 not found (125418)
The information in this article applies to:
- Microsoft FoxPro for MS-DOS 2.6
- Microsoft FoxPro for MS-DOS 2.6a
This article was previously published under Q125418
*****************************************************************
** - WARNING - **
** THE INFORMATION BELOW IS PRELIMINARY AND HAS NOT BEEN **
** CONFIRMED, EDITED OR TESTED BY MICROSOFT. USE ONLY **
** WITH DISCRETION. **
*****************************************************************
SYMPTOMS
WARNING: The information in this article has not been confirmed
or tested by Microsoft. Some or all of the information in this
article has been taken from unconfirmed customer reports. ANY USE
BY YOU OF THE INFORMATION PROVIDED IN THIS ARTICLE IS AT YOUR OWN
RISK. Microsoft provides this information "as is" without warranty
of any kind, either expressed or implied, including but not limited
to the implied warranties of merchantability and/or fitness for a
particular purpose.
When generating a screen in the screen wizard, the following error message
is displayed:
Error in SCX: Objtype=1 Not Found
Genscrn Line Number: xx
Press any key to clean up and exit (or something equivalent)
CAUSE
The _GENSCRN system memory variable is not set to the default GENSCRN.PRG
program provided with FoxPro.
RESOLUTION
Reset _GENSCRN to the Foxpro default GENSCRN.PRG program, and then
recompile the screen(s).
Modification Type: | Major | Last Reviewed: | 10/15/2003 |
---|
Keywords: | kb3rdparty kberrmsg KB125418 |
---|
|