Can't Get Zone Information with Compaq Netflex II TR NIC (123965)
The information in this article applies to:
- Microsoft Windows NT Server 3.5
This article was previously published under Q123965 SYMPTOMS
When using the Compaq Netflex II Token Ring (TR) network interface card
(NIC) on a Windows NT 3.5 server, you are not able to get zone information.
Macintosh clients cannot see Windows NT 3.5 servers that use this NIC from
Chooser. You cannot get zone information either when you are first
configuring zones during the installation of Services for Macintosh, or
later, after restarting the server or Services for Macintosh.
CAUSE
This problem is caused by the way functional addresses (TR equivalent of a
multicast address) are added. There is no problem if the driver is written
so it completes calls synchronously. However, if a driver is written so
calls are made asynchronously, the request buffer becomes corrupted and no
routing information is passed.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5.
This problem was corrected in the latest U.S. Service Pack for Windows NT
version 3.5. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Modification Type: | Major | Last Reviewed: | 10/3/2003 |
---|
Keywords: | KB123965 |
---|
|