SNA Server Err Msg: Event 23, Outage Code "2D" (Abnormal Resp.) (123748)
The information in this article applies to:
- Microsoft SNA Server 2.0
- Microsoft SNA Server 2.1
- Microsoft SNA Server 2.11
- Microsoft SNA Server 2.11 SP1
- Microsoft SNA Server 2.11 SP2
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 SP1
This article was previously published under Q123748 SYMPTOMS
If the Microsoft SNA Server Synchronous Data Link Control (SDLC) connection
is configured with the Maximum BTU Size set to a value less than the
maximum frame size of the remote system (set using the PU macro MAXDATA
parameter in VTAM), the following SNA Server connection failure may be
logged in the Windows NT application event log:
Event 23, Outage code "2D" (abnormal response)
CAUSE
The abnormal response error occurs if the host banner screen (that is, the
USSTAB message 10 screen) exceeds the Maximum BTU size set in SNA Server.
Because the maximum frame size is not negotiated until a BIND takes place,
the SNA Server's maximum frame size can be exceeded.
RESOLUTION
To correct this problem, change the SNA Server Maximum BTU size to
match the value used on the remote system.
NOTE: If an IBM SDLC adapter or MicroGate SDLC adapter is being used with
SNA Server, the maximum frame size supported by Microsoft SNA Server is 521. Other SDLC adapters do not have this restriction.