SYMPTOMS
Your Gateway2000 computer with a Mitsumi CD-ROM drive hangs on the first re-
boot during a Windows NT 3.5 install or upgrade.
CAUSE
Windows NT automatic hardware detection fails during the first re-boot of
installation with the Mitsumi drive. On subsequent re-boots, NT does not
repeat the hardware detection because it has already recorded information
about the machine in the registry.
WORKAROUND
Remove the CD-ROM interface card (a very small card with a cable leading to
the CD-ROM). Re-boot and complete the installation. Once you have NT
installed to the point where you can log on, turn off your computer and
reinsert the card.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5.
We are researching this problem and will post new information here in the
Microsoft Knowledge Base as it becomes available.