Err Msg: KERNEL_STACK_INPAGE_ERROR (0x77) w/Future Domain 1680 (117723)



The information in this article applies to:

  • Microsoft Windows NT Server 3.1
  • Microsoft Windows NT Workstation 3.1
  • Microsoft Windows NT Advanced Server 3.1

This article was previously published under Q117723

SYMPTOMS

If you are using a Future Domain 1680 SCSI Controller with a BIOS earlier than 3.2, the following error message may appear:
KERNEL_STACK_INPAGE_ERROR (0x77)

CAUSE

Even though this board is listed under the Windows NT hardware compatibility list, using an earlier BIOS may cause Windows NT to fail.

RESOLUTION

To avoid this problem, upgrade to a later BIOS. Call Future Domain technical support at (800) 879-7599 for information on obtaining a BIOS upgrade.

The Future Domain product discussed here is manufactured by a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Modification Type:MajorLast Reviewed:11/20/2003
Keywords:kbHardware KB117723