X400: Gateway Crashes on Receipt of a DEC VAX Delivery Report (115357)
The information in this article applies to:
- Microsoft Mail Gateway to X.400 3.0
This article was previously published under Q115357 SYMPTOMS
The X.400 gateway crashes upon receipt of a DEC VAX delivery report.
CAUSE
The DEC VAX delivery report includes a NIST-defined internal trace field
that is in the message's contents as well as in the envelope.
The internal trace should not reside in the content field. The file should
be declared bad, the report moved to the "bad" subdirectory, and the logs
notified of an "incorrect" report.
RESOLUTION
A supported fix that corrects this problem is now available from Microsoft,
but has not been fully regression tested and should be applied only to
systems experiencing this specific problem.
To resolve this problem, contact Microsoft Product Support Services to
obtain the fix. For a complete list of Microsoft Product Support Services
phone numbers and information on support costs, please go to the following
address on the World Wide Web:
The English version of this fix should have the following file attributes
or later:
File Name Version
----------------------
X400gate.exe 3.0.2
This hotfix has been posted to the following Internet location as
X400gy2k.exe:
STATUS
Microsoft has confirmed this to be a problem in Microsoft Mail Gateway to
X.400 version 3.0.
MORE INFORMATION
DEC fixed the problem, although older versions of the software sometimes
crop up and cause this problem.
Modification Type: | Major | Last Reviewed: | 10/16/2002 |
---|
Keywords: | kbbug kbQFE KB115357 |
---|
|