PRB: Project Editor Gives "Invalid File Format" at Startup (115214)
The information in this article applies to:
- Microsoft Multimedia Viewer Publishing Toolkit 2.0
- Microsoft Multimedia Viewer Publishing Toolkit 2.0a
This article was previously published under Q115214 SYMPTOMS
Upon starting the Viewer Project Editor, an "Invalid File Format"
error is displayed.
CAUSE
Viewer located and attempted to use an older version of the CMDIALOG.VBX
custom control.
RESOLUTION
Check the date and time of the CMDIALOG.VBX file located in the
\WINDOWS\SYSTEM directory. If the file is dated before 3/22/93, it will
need to be replaced. This file can be found on the Viewer CD in the \SYSTEM
directory.
If the CMDIALOG.VBX file located in the \WINDOWS\SYSTEM directory has a
date later than 3/22/93, check the directories specified in your MS-DOS
path (especially those that precede the Windows directory) for the presence
of a duplicate. If one is found, keep only the most recent copy and delete
the others.
Modification Type: | Minor | Last Reviewed: | 10/14/2003 |
---|
Keywords: | KB115214 |
---|
|