RAS Can't Connect at 14400 or 19200 on TI 4000e (114688)



The information in this article applies to:

  • Microsoft Windows NT Server 3.1
  • Microsoft Windows NT Workstation 3.1

This article was previously published under Q114688

SYMPTOMS

You cannot connect from LAN Manager Remote Access Services (RAS) version 1.1a on a TI 4000e series portable computer to a Windows NT server at 14400 or 19200 bits per second (bps). After the number is dialed, you do not see any confirmation that the computers connected.

The modem sold by TI for use with the 4000e computers is a modified U.S. Robotics Sportster 14400.

WORKAROUND

To enable this modem to work with RAS 1.1a you need to modify the MODEM.INF file in the SYSTEM32\RAS sub-directory. Before you make any changes to this file, make a backup copy.

In MODEM.INF, find two lines that contain the following

<cr><If>CONNECT<carrierbps>/ARQ<cr><If>


Change both lines to read

<cr><If>CONNECT<carrierbps>/SEL<cr><If>



RAS should now be able to dial in and connect properly.

Modification Type:MajorLast Reviewed:10/28/2003
Keywords:kbnetwork KB114688