NE2000 Failure on Windows NT/NTAS (113225)
The information in this article applies to:
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q113225 SYMPTOMS
Running a network application on an Intel 80486 Windows NT client with a
NE2000 network adapter connected to a Windows NT server results in a lost
network connection. These errors are displayed:
The network path was not found.
System Process - lost delayed write data:
The system was attempting to transfer file data from buffers to
<\address\address>. The write operation failed and only some of
the data may have been written to the file.
CAUSE
During performance tests, the NE2000 card stops transmitting data, although
it still responds to polls from the server.
STATUS
Microsoft has confirmed this to be a problem in Windows NT and Windows NT
Advanced Server version 3.1. This problem has been corrected in Windows NT
Workstation and Windows NT Server version 3.5.
The products included here are manufactured by vendors independent of
Microsoft; we make no warranty, implied or otherwise, regarding these
products' performance or reliability.
| Modification Type: | Major | Last Reviewed: | 11/20/2003 |
|---|
| Keywords: | kbHardware KB113225 |
|---|
|