WFWG 3.11 May Fail After Upgrading (Missing SlotNumber= Entry) (108802)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q108802 SYMPTOMS
If you are using a MicroChannel or EISA network interface card (NIC) and
upgrade from Windows for Workgroups version 3.1 to Windows for Workgroups
3.11, your system may not work correctly if your PROTOCOL.INI file does
not contain a SlotNumber entry.
CAUSE
Under Windows for Workgroups version 3.1 the NDIS version 2.0 driver
scans the slots to determine the correct SlotNumber. Therefore, the
SlotNumber entry in the PROTOCOL.INI file is optional. Under Windows for
Workgroups version 3.11, the NDIS version 3.0 driver does not scan the
slots to determine the correct SlotNumber.
Since you upgraded from Windows for Workgroups 3.1 or 3.11, the network
card detection code was not used during Setup. As a result, your
PROTOCOL.INI file does not contain a SlotNumber entry. If there isn't a
SlotNumber entry in the PROTOCOL.INI file, the NDIS version 3.0 driver
defaults to slot number 1.
WORKAROUND
To work around this problem add the correct SlotNumber= entry to the
network interface card section of the PROTOCOL.INI. For example:
[MS$IBMTRA]
SlotNumber=2
Modification Type: | Major | Last Reviewed: | 10/10/1999 |
---|
Keywords: | KB108802 |
---|
|