RAS May Not Function on a Shared Network Installation (107809)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q107809 SYMPTOMS
When you run a shared network installation (SETUP /N) of Microsoft Windows
for Workgroups version 3.11, starting Remote Access Services (RAS)
generates the following error:
Cannot load phone book or RAS manager data. Error 657: the device .INF
file could not be opened.
CAUSE
The above error message is generated when PAD.INF and SWITCH.INF are marked
read-only.
WORKAROUND
You may be able to use RAS with a shared Windows for Workgroups
installation if only one person on the network attempts to use RAS and you
remove the read-only attribute from PAD.INF and SWITCH.INF. (If the shared
directory is located on a server, full permissions must also be granted.)
STATUS
RAS was not designed to run under a shared Windows for Workgroups
installation. This functionality was not tested by Microsoft and is not
supported.
Modification Type: | Major | Last Reviewed: | 11/5/1999 |
---|
Keywords: | KB107809 |
---|
|