SCSI Bus Reset Problems with Ultrastor 14f Controller (107370)
The information in this article applies to:
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q107370 SYMPTOMS
Backup generates the following error message when doing a back up with an
Ultrastor 14f controller that has both a SCSI tape drive and a SCSI hard
disk attached to it:
Fatal error on drive 1
CAUSE
This problem appears to be caused by a reset of the SCSI bus. The reset is
caused by a timeout waiting for the hard disk to respond. This problem
typically occurs on machines with slow hard disks.
WORKAROUND
To work around this problem, do one of the following:
- Use a different model SCSI controller
-or-
- Isolate the tape drive and the hard disk drive to two different
Ultrastor 14f controllers.
Modification Type: | Major | Last Reviewed: | 11/20/2003 |
---|
Keywords: | kbHardware KB107370 |
---|
|