BUG: Redirection of Input to a Spawned PowerStation App Fails (106723)
The information in this article applies to:
- Microsoft FORTRAN PowerStation for MS-DOS 1.0
- Microsoft FORTRAN PowerStation for MS-DOS 1.0a
This article was previously published under Q106723 SYMPTOMS
PowerStation applications spawned with either SYSTEMQQ or RUNQQ hang when
input is redirected from a file. Also, the input is split and directed at
both the application and the console.
CAUSE
The MS-DOS extender that comes with PowerStation does not handle console
input the same way as MS-DOS does. The hang occurs because the spawned
application is waiting for an end-of-file (EOF).
STATUS
Microsoft has confirmed this to be a problem in FORTRAN PowerStation
version 1.0 and version 1.0a for MS-DOS.
This is not a problem in FORTRAN PowerStation 32.
Modification Type: | Major | Last Reviewed: | 10/2/2003 |
---|
Keywords: | KB106723 |
---|
|