SPX-Compatible Applications and Windows for Workgroups 3.11 (106054)
The information in this article applies to:
- Microsoft Windows for Workgroups 3.11
This article was previously published under Q106054 SYMPTOMS
If the frame type being used on your Novell NetWare server is not set
to Ethernet_802.3, SPX-compatible applications, such as RConsole, may
not work correctly under Windows for Workgroups 3.11.
For example, if you start the RConsole application, some servers may
be missing from the list of servers to administer. This problem occurs
if the server's frame type is set to Ethernet_II, Ethernet_802.2, or
Ethernet_SNAP.
CAUSE
This problem occurs because the Windows for Workgroups server defaults
to the 802.3 frame type.
RESOLUTION
To correct this problem, choose the Network Setup icon and change the
frame type for the Windows for Workgroups IPX/SPX-compatible protocol
to the same frame type as the NetWare server.
Modification Type: | Major | Last Reviewed: | 10/31/1999 |
---|
Keywords: | KB106054 |
---|
|