SYMPTOMS

If the frame type being used on your Novell NetWare server is not set to Ethernet_802.3, SPX-compatible applications, such as RConsole, may not work correctly under Windows for Workgroups 3.11.

For example, if you start the RConsole application, some servers may be missing from the list of servers to administer. This problem occurs if the server's frame type is set to Ethernet_II, Ethernet_802.2, or Ethernet_SNAP.

CAUSE

This problem occurs because the Windows for Workgroups server defaults to the 802.3 frame type.

RESOLUTION

To correct this problem, choose the Network Setup icon and change the frame type for the Windows for Workgroups IPX/SPX-compatible protocol to the same frame type as the NetWare server.

Modification Type:MajorLast Reviewed:10/31/1999