FIX: SR2TEST GP Faults During Object Shutdown (104141)
The information in this article applies to:
- Microsoft OLE Libraries for Windows and Win32s 2.0
This article was previously published under Q104141 SYMPTOMS
A general protection (GP) fault occurs when calling IOleObject::Close()
on an SR2TEST object.
CAUSE
SR2TEST does not properly handle the case in which IOleObject::Close()
is called after OleInPlaceObject::UIDeactivate() without first calling
IOleInPlaceObject::InPlaceDeactivate().
RESOLUTION
Call IOleInPlaceObject::InPlaceDeactivate() before calling
IOleObject::Close.
STATUS
Microsoft has confirmed this to be a problem in OLE version 2.0. This
problem was corrected in OLE version 2.01.
| Modification Type: | Major | Last Reviewed: | 10/15/2002 |
|---|