FIX: Prefix Bytes Are Order-Dependent in CodeView 4.0x (103721)
The information in this article applies to:
- Microsoft CodeView for MS-DOS 4.0
- Microsoft CodeView for MS-DOS 4.01
This article was previously published under Q103721 SYMPTOMS
The disassembler, which is used to display mixed source and assembly
or assembly in CodeView, is sensitive to the order in which the 66h
and 67h prefix bytes occur in 32-bit instructions. If the order is 67h
66h, then the instruction is disassembled as:
67668B03 MOV AX,WORD PTR [EBX]
CodeView incorrectly shows AX as the destination operand. However, if
the order is 66h 67h, then the instruction is disassembled as:
66678B03 MOV EAX,DWORD PTR [EBX]
In this case, CodeView correctly shows EAX. The MASM version 6.x
program shown below demonstrates the problem.
STATUS
Microsoft has confirmed this to be a problem in CodeView versions 4.0
and 4.01. The problem was corrected in CodeView version 4.1.
Sample Code
; Assemble options needed: /Zi
.MODEL small
.386
.STACK 4096
.CODE
.startup
loc1:
mov eax, [ebx]
loc2:
ORG loc1
DB 66h, 67h ; This forces the prefix bytes to 66h 67h
ORG loc2
loc3:
mov eax, [ebx]
loc4:
ORG loc3
DB 67h, 66h ; This forces the prefix bytes to 67h 66h
ORG loc4
.exit 0
END
Modification Type: | Major | Last Reviewed: | 9/30/2003 |
---|