Troubleshooting 16-Bit Windows Applications (103656)



The information in this article applies to:

  • Microsoft Windows 2000 Server
  • Microsoft Windows 2000 Advanced Server
  • Microsoft Windows 2000 Professional
  • Microsoft Windows 2000 Datacenter Server
  • Microsoft Windows NT Server 3.1
  • Microsoft Windows NT Server 3.5
  • Microsoft Windows NT Server 3.51
  • Microsoft Windows NT Server 4.0
  • Microsoft Windows NT Workstation 3.1
  • Microsoft Windows NT Workstation 3.5
  • Microsoft Windows NT Workstation 3.51
  • Microsoft Windows NT Workstation 4.0
  • Microsoft Windows NT Advanced Server

This article was previously published under Q103656
For a Microsoft Windows XP version of this article, see 314495.
Many different 16-bit applications designed to run under Windows 3.1 have been tested with Windows NT and later. When you are troubleshooting a 16-bit Windows-based application that is not working properly under Windows NT and later, the following items should be taken into consideration:

  • If possible, verify that the application works correctly under Windows 3.0 and 3.1.
  • If the application requires a VxD (virtual device driver), it will not work properly under Windows.
  • If the application requires Windows 3.0 or 3.1 to be running in 386 enhanced mode, the application will not function properly on either the DEC Alpha or MIPS versions of Windows at this time because these platforms currently emulate only the Intel 80286 architecture.
  • Check Print Manager to see that a default printer has been selected. Some applications (such as Microsoft Word version 2.0 for Windows) will not function properly under Windows unless a default printer has been selected.
  • Make sure that any dynamic link libraries (DLLs) used by the application are both current and locatable by the application (either on the system path or explicitly defined within the application or working directory.)
  • Make sure that the default items in the CONFIG.NT and AUTOEXEC.NT files are present and in the proper order.

    In Windows NT 3.1, CONFIG.NT contains the following commands by default:

          files=50
          lastdrive=k
          fcbs=4,0
          dos=high, umb
          device=%SystemRoot%\system32\himem.sys
    				
    In Windows NT 3.51 and later, the CONFIG.NT contains the following commands by default:
          dos=high, umb
          device=%SystemRoot%\system32\himem.sys
          files=20
    				
    AUTOEXEC.NT contains the following commands by default:
          @echo off
          lh %SystemRoot%\system32\mscdexnt.exe
          lh %SystemRoot%\system32\redir
          lh %SystemRoot%\system32\dosx
    			
  • Any environment variables required by the Windows-based application should be in the AUTOEXEC.BAT file; if they are, Windows will use them appropriately.

    Note that if any changes are made to variables related to the Windows 3.0 or 3.1 subsystem (WOWEXEC.EXE), the user may have to restart the computer in order for these changes to be implemented.
  • Determine whether Windows has been installed as a stand-alone operating system or as an upgrade of a previous Windows 3.0 or 3.1 installation. If it is an upgrade, information from the WIN.INI and/or SYSTEM.INI files may have not been correctly copied into the Windows Registry database.

    To correct this problem, you may have to either migrate these settings again, or reinstall the application that is not working.

    For help with migrating application information into the Windows Registry, query on the following reference words in the Microsoft Knowledge Base:

    migrate and WIN.INI

  • Try running the application in a separate memory space by editing the icon or shortcut's properties and checking the appropriate checkbox.

Modification Type:MajorLast Reviewed:5/6/2003
Keywords:kb3rdparty kbinterop KB103656