Archive 2150/2250 Firmware Error Causes Under Runs (102377)
The information in this article applies to:
- Microsoft Windows NT Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q102377 SYMPTOMS
The Archive 2150/2250 QIC SCSI tape drive (Viper 150, Viper 250) does
not correctly respond with the number of bytes transferred. This is a
condition known as an "under run."
CAUSE
A firmware error causes the Archive 2150/2250 to do this.
WORKAROUND
Use one of the SCSI miniports that have been tested out and correctly
handle under runs: AHA154X.SYS, AHA174X.SYS, SPARROW.SYS,
FD16_700.SYS, FD8XX,SYS, and SPOCK.SYS. Except for the Ultrastor 24,
these are all the "core" adapters.
Modification Type: | Major | Last Reviewed: | 11/20/2003 |
---|
Keywords: | kbother KB102377 |
---|
|