How FoxPro Passes Parameters to Subroutines (101025)



The information in this article applies to:

  • Microsoft Visual FoxPro for Windows 3.0
  • Microsoft FoxPro for Windows 2.5
  • Microsoft FoxPro for Windows 2.5a
  • Microsoft FoxPro for MS-DOS 2.0
  • Microsoft FoxPro for MS-DOS 2.5
  • Microsoft FoxPro for MS-DOS 2.5a

This article was previously published under Q101025

SUMMARY

By default, FoxPro passes parameters to procedures (subroutines called with a DO <subroutine> command) by reference and parameters to functions [subroutines called with a =<subroutine>() or ?<subroutine>() command] by value. The information below describes how parameters are passed to subroutines.

MORE INFORMATION

When parameters are passed by value, a copy of the original variable is made in the routine. The variable declared in the subroutine is a different variable from the original variable. When control is passed back to the calling program, the variables declared in the routine are released and the value of the original variable is not changed.

When parameters are passed by reference, a reference to the original variable is made in the routine. Any change made to the variable in the subroutine is reflected in the calling program.

Passing Parameters to User-Defined Functions

By default, parameters are passed by value to user-defined functions. In essence, any change made to the variables declared as parameters in the subroutine will not affect the original variables in the calling program. For example:
   * Main program
   CLEAR
   mvar1=1
   mvar2=2
   mvar3=ADDIT(mvar1)   && Passing mvar1 as a parameter: by value
   ?
   ?"Value of memory variables after the routine is executed"
   DISP MEMO LIKE m*
   ?
   ?"The value of mvar1 is unchanged"

   FUNCTION ADDIT
   PARAMETER mpar1
   mpar1=mpar1+1    && Copy of mvar1 is incremented
   mvar3=mpar1+1     && Variable to be returned to the calling program.
   ?"Value of memory variables in the routine"
   DISPLAY MEMORY LIKE m* && mvar1=1 and mpar1=1
   RETURN mvar3      && Value returned to the calling program mvar3
				
To pass a parameter by reference to a user-defined function, use the at sign (@) before the variable passed. For example:
   mvar3=ADDIT(@mvar1)
				
To change the default and pass all the parameters by reference, use SET UDFPARMS command. For example:

SET UDFPARMS TO REFERENCE

Passing Parameters to Procedures

By default, FoxPro passes parameters by reference to procedures. Any changes made to variables in the subroutine will be made to the original variable. Additionally, FoxPro hides the original variables passed as parameters in the subroutine. For example:
   * Main program
   CLEAR
   mvar1=1
   mvar2=2
   DO ADDIT WITH mvar1  && Passing mvar1 as a parameter by reference
   ?
   ?"Value of memory variables after the routine is executed"
   DISPLAY MEMORY LIKE m*
   ?
   ?"The value of mvar1 is modified"

   PROCEDURE  ADDIT
   PARAMETER mpar1
   mpar1=mpar1+1            && Reference to mvar1 is incremented
   ?"Value of memory variables in the routine"
   DISPLAY MEMORY LIKE m*   && mvar1=2 and mpar1= @mvar1
				
To pass a parameter to a procedure by value, use parentheses around the variable. For example:

DO ADDIT WITH (mvar1)

REFERENCES

"Language Reference," version 2.5, page L3-1012

"Using FoxPro Version 2," Slater and Arnott, pages 613-614, Que, 1992

Modification Type:MajorLast Reviewed:12/3/2003
Keywords:kbenv KB101025