Error 2 Stops OTN Installation of DCA Token Ring Adapters (100516)
This article was previously published under Q100516
SYMPTOMS
When performing an over-the-network (OTN) installation for LAN Manager
on an MS-DOS workstation using DCA's token ring adapter (IRMATRAC), the
installation copies all files from the server onto the MS-DOS workstation,
then displays this error message:
An error occurred while reading the file: PROTOCOL.INI
Error Code:2
CAUSE
There is an error in the [IRMATR] section in NSETUP.INF file on server
(LANMAN\NINSTALL). The NSETUP.INF file contains information for finding
the adapter driver (IRMATR.DOS) and the PROTOCOL.INI, but its PROTOCOL.INI
path in section [IRMATR] is defined: RIVERS\TOKENTNG\IRMATRAC\PROTOCOL.INI.
The "TOKENTNG" should be TOKENRNG.
"Error Code:2" is an extended error message number that means "file not
found." These errors are listed in the "MS-DOS Programmer's Reference."
RESOLUTION
Correct the PROTOCOL.INI path in NSETUP.INF, then perform the OTN
installation again.
Modification Type: |
Major |
Last Reviewed: |
7/30/2001 |
Keywords: |
KB100516 |
|